제조 > 좌표측정기(CMM) > Probe Path > Outputting Operator Instructions
Outputting Operator Instructions
To output operator instructions for a CMM model, you have to set up a DMIS TEXT table for this model. This table contains all the items that can be output through DMIS TEXT. Whether an item will be output or not is determined by the flag value. The default flag value for all items is "NO". Change it to one of the following values if you want the item to be output:
OPER—Outputs the TEXT/OPER command with the selected item into the DMIS file.
OUTFIL—Outputs the TEXT/OUTFIL command with the selected item into the DMIS file.
MAN—Outputs the TEXT/MAN command with the selected item into the DMIS file.
The following items are output once per DMIS file:
PART_NAME
DATE_TIME
The following items are output once per operation:
OPERATION_NAME
OPERATION_COMMENTS
LAYER_NAME
PROBE_TABLE
ONLY_OUTPUT_USED_PROBES
The following items are output once per CMM step:
STEP_NAME
STEP_TYPE
FEATURE_ID
REF_CSYS
MEASURE_FEEDRATE_&_UNITS
SAFE_FEEDRATE_&_UNITS
PROBE_NAME
PROBE_TYPE
PROBE_TIP_NUMBER
PROBE_PITCH_ANGLE
PROBE_ROLL_ANGLE
PROBE_POSITION_NUMBER
PROBE_COMMENTS
PROBE_PARAMETERS
REGISTER