About the CMM VERIFY Dialog Box
The following elements are common for all Verify steps:
• Name—Supply a meaningful name for the step, to be used in namelist menus and system messages. This element is optional. If you do not supply a name, the step will have a default name generated by the system (for example, "10: VER01, Operation: OP010").
• Tolerance—Select a dimension or geometric tolerance to verify.
• Feature(s)—The measured or constructed entity, or entities, that the dimension or gtol controls.
• Datum(s)—The measured or constructed entity, or entities, that the dimension or gtol is based upon.
• Ref Csys—Change the coordinate system to be used as reference for this Verify step.
• Comment—Enter comment to be output before the DMIS block for the step. This element is optional.