To Insert a New CL Command
1. From the SMT NC SEQUENCE dialog box, select the CL Command element and click Define. The SMM CL COMMAND dialog box opens.
2. Type the command name in the Command ID window.
3. Using the Command Wizard, select the desired commands. You can edit commands in the Command Edit Area window.
4. Place the CL command using the placement buttons. The following options are available:
◦ —Click the tool path to select the command placement. You can pick anywhere on the tool path as it is defined so far; note that you cannot click a cut motion that is not yet incorporated in the tool path.
◦ —The CL command is output before the first cutter position of the NC sequence (or the first cutter position of the operation if you are optimizing an operation tool path).
◦ —The CL command is output after the last cutter position of the NC sequence (or the last cutter position of the operation if you are optimizing an operation tool path).
5. Click > to save the CL command.
6. Click > to finish.