Specification Override during Fitting Insertion
Use the sample files provided at
<Creo load point>\Common Files\help\sample_models\piping when working in this exercise. It is recommended that you create a copy of the
piping folder on your computer and
set up piping data before you start working with the tutorial.
Create a Pipe Segment
1. On the
Home tab, click
New. The
New dialog box opens.
2. Under
Type, select
Assembly.
3. Click OK to create a new assembly.
4. Click > . The Piping tab opens.
5. On the Piping tab, select the Spec Driven check box.
6. Click
Create Pipe. The
Create Pipeline dialog box opens.
7. In the Size box, select 100A.
8. In the Number box, type 1.
9. Click OK. The Create Pipeline dialog box closes.
10. Click
Set Start. The
Define Start dialog box opens.
11. Select ASM_DEF_CSYS in the graphics window.
12. Click OK. The Define Start dialog box closes.
13. Click
Extend. The
Extend dialog box opens.
14. In the z box, type 1000 and press ENTER.
15. Click OK. A pipe segment is created.
Insert a Fitting
1. Click
Insert Fitting. The
Insert Fitting dialog box opens.
2. Select the pipe segment in the graphics window.
3. Select the Specification check box and select ha.
4. Click OK. A fitting is inserted.
5. Click
Piping Info. The
Report Pipeline dialog box opens.
6. Under
Type, click
to display the fitting report.
7. Select a fitting component in the graphics window and click OK in the Select dialog box. The INFORMATION WINDOW opens.
| The INFORMATION WINDOW displays the values of Pipe Spec and Fitting Spec as defined. |