To Check Waterline Circuits
1. On the
Mold or
Cast tab, click
Mold Analysis. The
Mold Analysis dialog box opens.
2. Under Type, select Waterlines, and under Definition > Part, select a part.
3. Under Waterline, select one of the options:
◦ All Waterlines
◦ Select Waterlines
◦ Select Surfaces
4. Under Clearance, click and enter a minimum clearance for the waterline.
5. Click Compute. The results appear in the Results box.
Red indicates that the water line is closer than the clearance; green indicates that the water line is farther than the clearance.