Creo ModelCHECK > checks > PARAMCHECK (Parameter Format Errors)
  
PARAMCHECK (Parameter Format Errors)
Y/N/E/W
Checks that all standard parameters are present in the model and that they are of an acceptable type and format. This check is used only for user defined parameters and not for reserved and system parameters.
Standard parameters are defined by the PRT_PARAMETER and ASM_PARAMETER start configuration options.
If the ModelUPDATE mode is enabled, this check automatically corrects the type and value of parameters, if required.
Suggested Settings:
Inter
Batch
Regen
Save
E
E
W
W