PTC recommends that you set the Cabling configuration options before you create or open a new cabling assembly. |
After you set the configuration options, all the settings take effect immediately in the current Creo Parametric session. |
Configuration Option | Description | ||
align_cable_bundles | Aligns or unaligns newly created bundles at a point where they meet or branch out. By default, the bundles are aligned. If not, ensure that this option is set to yes before creating a network.
Values: yes*, no For more information, see To Align or Unalign Bundles. | ||
allow_bundle_flat_cables | Enables you to bundle the flat packing wires or cables into a cylindrical-shaped bundle. Values: yes, no* | ||
allow_freeze_failed_assy_comp | Determines how Creo Parametric handles assembly components that fail retrieval. Values: • yes—Enable the freeze component options. Assembly components that cannot be retrieved are automatically frozen at their last known locations in the assembly. You may have to perform specific actions to fix the assembly. • no*—Disable the freeze component options. Assembly components that cannot be retrieved are frozen only by regeneration. PTC recommends that you set the value for this option to yes. For more information, see To Convert Frozen Location. | ||
allow_logical_spool_editing | Determines if you can rename a spool or edit spool parameters for logical data spools. By default, this configuration option is set to no. Values: • yes—Options to rename and edit spool parameters for logical data spools are available. • no* —Options to rename and edit spool parameters for logical data spools are disabled. | ||
auto_xml_on_retrieve | Automatically loads Cabling Logical Reference from a XML file when retrieving the cabling assembly. Values: no*, yes | ||
auto_xml_on_save | Automatically creates an XML Logical Reference when saving a cabling assembly. Values: no*, yes | ||
autoroute_path_param_name | Sets the wire parameter to be used while selecting a path during automatic routing. Value: USE_PATH For more information, see About Network Paths. | ||
bundle_transition_create_method | Controls whether bundle transitions are created automatically or manually. Values: automatic*, manual | ||
cable_bundle_transition_length | Sets the length of the transition chamfer as a percentage of the larger diameter of the cable. A chamfer is not created when there is an insufficient distance between the two cable locations. Value: 50*, an integer from 1 to 250 | ||
cable_int_portions_for_clr | Values: • no*—Global clearance check for splice internal cable portions is excluded. • yes—Global clearance check for splice internal cable portions is included. | ||
cable_jacket_termination | Values: • Ports—Cable jackets are routed between the entry ports. • Network Ends*—Cable jackets are terminated at the network ends. | ||
cable_location_override_color | Overrides the system color set for cable locations. Enter RGB values from 0 to 255 separated by a space. By default, when this option is not set, the system color is used. For more information, see Setting Up the Cabling Environment. | ||
cable_segment_override_color | Overrides the system color set for cable segments. Enter RGB values from 0 to 255 separated by a space. By default, when this option is not set, the system color is used. For more information, see Setting Up the Cabling Environment. | ||
cables_with_hlr | Values: • no—Cables and locations show through objects in shaded mode display. • yes*—Cables and locations are hidden by other objects in shaded mode display. For more information, see About Location Points for Ribbon Cables. | ||
compare_spools_by_name | Compares spool data by name during a logical compare. Values: yes*, no | ||
default_cable_axis_location | Sets the default placement of the location on the selected axis. By default, the location is placed on the selected axis. If you select along, the system creates a location at each end of the axis. Values: • along—The Along Axis check box on the shortcut menu is selected, by default. • on*—The Along Axis check box on the shortcut menu is cleared, by default. | ||
display_duplicate_harness_msg | Displays or does not display a warning message when duplicate harnesses are found in an assembly. Values: yes*, no | ||
display_internal_cable_portion | Values: no*, yes If set to yes, internal cable portions are displayed for wires that have been manually set to yes in the Setup Cable Paths dialog box for each individual splice and custom component. You can override this option from Cable display settings section, underEntity Display in the PTC Creo Parametric Options dialog box. | ||
display_route_cable_preview | Shows a preview of the path routed cables will follow. On large harnesses setting to no will improve system performance. Values: yes*, no | ||
display_thick_cables | Sets the default startup mode. Values: • yes—Displays thick cables and wires. • no*—Displays centerlines of wires and cables only. You can override this option in the Cabling mode in the following ways: • From Cable display settings section, under Entity Display in the PTC Creo Parametric Options dialog box • Selecting Thick Cables from the graphic toolbar | ||
enable_cable_channel | Activates the following channel options: • Channel • By Cross Section The channel options are available in the Route overflow menu. By default, the channel options are hidden. Values: no*, yes | ||
freeze_failed_cable_locations | Determines how Creo Parametric handles cable locations that fail retrieval. Values: • yes—Freezes the cable location at its last known location. • no*—If the reference feature of the component is missing, Creo Parametric fails the location. You must perform specific actions to fix the failed location. PTC recommends that you set the value for this option to yes. If the component is missing, Creo Parametric freezes the location at its last known location. For more information, see About Cable Locations with Missing References. | ||
full_hlr_for_cables | If set to partial or none, some lines that should be hidden behind cables are visible in the wireframe mode. Using the Model Display dialog box, under the Edge/Line tab, you can set the Cable HLR options for the current session. Values: • full*—Removes hidden lines from view when cables hide other geometry. Use when the Display Style is Hidden Line in the Environment dialog box. • partial—Cables hide other non-interfering cables except when cables route together between same locations. • none—Displays hidden lines (faster) that should be hidden behind cables or wires.
For more information, see Setting Up the Cabling Environment. | ||
harn_start_model_dir | Provides the complete path to the directory containing the harness start parts. | ||
harn_tang_line_display | Display the tangent lines between the segments of a cable in the Thick Cable Display mode. Values: yes*, no | ||
ignore_bundles_in_find_cables | Include the bundles and overbraids when querying the model or logical data for unrouted items. The items that are found are listed in the items found section of the Find Cables dialog box. Values: no*, yes If set to yes, the bundles and overbraids are not included in the items found section. | ||
limit_ref_des_label_reorder | Controls the reordering of manually positioned Reference Designator Labels. Values: yes*, no yes*—This option prevents the auto ordering of manually positioned labels. no—This option enables auto ordering of manually positioned reference designation labels. | ||
network_location_override_color | Overrides the system color set for network locations. Enter RGB values from 0 to 255 separated by a space. By default, when this option is not set, the system color is used. For more information, see Setting Up the Cabling Environment. | ||
network_segment_override_color | Overrides the system color set for network segments. Enter RGB values from 0 to 255 separated by a space. By default, when this option is not set, the system color is used. For more information, see Setting Up the Cabling Environment. | ||
pro_cbltrm_dir | <home directory> Sets the default directory from which terminators are retrieved by default. Use the full path name, for example: /home/users/terminators. The default is the current working directory. | ||
pro_spool_dir | <home directory> Sets the default directory from which the spools are retrieved by default. Use the full path name, for example: /home/users/spools. The current working directory is the default directory. For more information, see Creating Spools. | ||
prompt_add_to_main_bundle | Controls display of a message when modifying a branch bundle while adding a wire or a cable. Values: yes*, no yes*—Displays a message box when adding a wire or a cable to the branch bundle. Click Yes in the message box to add the wire or cable to the main bundle along with the branch bundle. no—Do not display the message box. The wire or cable is not added to the main bundle. | ||
prompt_extract_from_branches | Controls display of a message when the wire or cable to be extracted is routed through a branch bundle. Values: yes*, no yes*— Displays a message box when the wire or cable to be extracted is routed through a branch bundle. Click Yes in the message box to automatically extract the wire or cable from both the branch and the main bundles. no—Do not display the message box. The wire or cable is not extracted from the branch bundle. | ||
ribbon_cable_flat_direction | Values: • y_axis—Flat ribbon cables are attached to the Y-axis of entry ports. • x_axis—Flat ribbon cables are attached to the X-axis of entry ports. For more information, see About Entry Port for Ribbon Cables. | ||
smaller_bundle_min_bend_rad | Specifies whether to consider the thickness of the bundle while setting up the minimum bend radius. Values: yes, no* | ||
template_harnesspart | Sets the default template to be used for the harness part model. Values: • inlbs_harn_part.prt*—The unit of measure for the harness part model is inches. • mmns_harn_part.prt—The unit of measure for the harness part model is millimeters. For more information, see To Create a Harness. | ||
trace_thru_splice_connector | Report the from/to connectors of the cables passing through the splices. Values: yes, no* | ||
update_loom_bundle_data | When working with legacy harnesses, you may encounter the following issues: • incorrect bundle thickness • missing portion of the wire path Setting this configuration option to yes will automatically fix issues related to wire paths and bundle thickness. Values: yes, no* | ||
update_pre_16_cable_layers | Updates the pre-release 16.0 harnesses. Values: no*, yes If set to yes, automatically updates the harnesses containing cables routed prior to Release 16.0 when retrieved to comply with new display standards. | ||
cable_stripes_file | Sets the path for the striped appearance (.csv) file. | ||
edit_cable_stripes_file | Values: • Yes— Allows user to define new appearances, and edit and save appearances locally on their machine. • No- User can use the appearances from the library. Only the super user or the one with administrative rights can define striped appearances. The default value is Yes. | ||
auto_assign_tiewrap_designation | Assigns the default tie wrap feature name automatically as a tie wrap designation label, to create a designated feature. • yes— Assigns the tie wrap feature automatically to the tie wrap feature tool. • no*— Does not automatically assign the tie wrap feature name to the tie wrap feature tool to create a designated feature. The default value is no. | ||
auto_assign_markers_designation | Assigns the default marker feature name automatically as a marker designation label, to create a designated feature. • yes— Assigns the marker feature automatically to the marker feature tool. • no*— Does not automatically assign the marker feature name to the marker feature tool to create a designated feature. The default value is no. |