BUNDLE PARAMETER | DESCRIPTION | ||
ADDITIONAL_NAMES | Specify additional names to identify the bundle. For example, a MIL-SPEC number. Format: ADDITIONAL_NAMES value Example: ADDITIONAL_NAMES M45G | ||
ASSIGNED_THICKNESS | Specifies a bundle thickness to be assigned to a bundle. The value of this parameter overrides any thickness computed by the system. Format: ASSIGNED_THICKNESS value Example: ASSIGNED_THICKNESS 1.125 | ||
ASSIGNED_MIN_BEND_RADIUS | Specifies a minimum bend radius to be assigned to a bundle. The value of this parameter overrides any minimum bend radius computed by the system. Format: ASSIGNED_MIN_BEND_RADIUS value Example: ASSIGNED_MIN_BEND_RADIUS 2.5 | ||
BUNDLE_TYPE | Specifies the type of bundle. Use ROUND for a circular grouping of bundle components and FLAT for a flat type of grouping. Format: BUNDLE_TYPE value Example: BUNDLE_TYPE round | ||
LINESTYLE | Changes the line style for cable or sheath spools. If you set this parameter for a sheath spool, the line styles assigned to a bundle overrides this parameter value. The following line styles are permitted: SOLID FONT (default), DOTFONT, CTRLFONT, PHANTOMFONT, DASHFONT, CTRLFONT_S_L, CTRLFONT_L_L, CTRLFONT_S_S Format: LINE STYLE style Example: LINE STYLE dotfont | ||
MATERIAL_DENSITY | Assigns weight or unit length to the bundle. Format: MATERIAL_DENSITY value Example: MATERIAL_DENSITY 12 | ||
MAX_ALLOWED_LENGTH | Maximum permitted length. It can be used, for example, to avoid signal degradation. Format: MAX_ALLOWED_LENGTH value Example: MAX_ALLOWED_LENGTH 100 | ||
MIN_ALLOWED_DIST | Minimum permitted distance between parallel cables. It can be used, for example, to avoid interference. Format: MIN_ALLOWED_DIST value Example: MIN_ALLOWED_DIST 2.5 | ||
MIN_BEND_RADIUS | This read only value is equal to either the largest minimum bend radius of any components of the bundle and the sheath spool or one-half the diameter of the bundle, whichever is greater. If this value is violated during routing, the location is not created. If you set ASSIGNED_MIN_BEND_RADIUS, it is used during routing instead of MIN_BEND_RADIUS. Format: MIN_BEND_RADIUS value Example: MIN_BEND_RADIUS 2.25 | ||
NAME | The name entered when creating a bundle. The bundle name can be changed by editing this value. Format: NAME text_string Example: NAME B34G | ||
OVERLAP_FACTOR (REQUIRED ONLY FOR BUNDLES USING A SHEATH SPOOL TYPE OF TAPE) | Indicates the overlapping you need to use when you wrap tapes sheathing. This factor is the ratio of the overlap and the width of the tape. Format: OVERLAP_FACTOR value Example: OVERLAP_FACTOR 0.33 | ||
SHEATH_SPOOL | Specifies the sheath spool used for a bundle. This value can be modified in Pro/TABLE to change the sheath spool used for a bundle. Format: SHEATH_SPOOL value Example: SHEATH_SPOOLred_sheath | ||
THICKNESS | This read only parameter is equal to the diameter of the bundle for ROUND type and the thickness of the bundle for FLAT type. This value is used to offset the bundle from surfaces when the location is placed. The value of this parameter changes to reflect the overall diameter of the bundle, including any sheathing thickness. If you modify the thickness later, you have to modify each location with an offset to account for the change. Format: THICKNESS value Example: THICKNESS 0.75 | ||
MAX_THICKNESS | Specifies a bundle diameter that the bundle cannot exceed.
|