Creo 教學專區 > Creo Flow Analysis 教學專區 > 其他教學專區 > Creo Flow Analysis Additional Tutorials > Tutorial 3 - Vortex Shedding > Vortex Shedding: Exercise 4—Assigning Boundary Conditions
  
Vortex Shedding: Exercise 4—Assigning Boundary Conditions
Specifying Inlet Boundary Conditions
1. Under Boundary Conditions, General Boundaries select inlet.
2. In the Model tab select the following values for the options listed:
FlowSpecified Velocity
MethodCartesian
Velocity—1,0,0 m/s
Specifying Outlet Boundary Conditions
1. Under Boundary Conditions select outlet.
2. In the Model tab select the following values for the options listed:
FlowSpecified Pressure Outlet
Pressure—0 Pa
Specifying Symmetry Boundary Conditions
1. Under Boundary Conditions select symmetry.
2. In the Model tab select the following values for the options listed:
FlowSymmetry
Specifying Volume Conditions
1. Under Domains, select VORTEX_SHEDDING.
2. In the Properties panel, Model tab, set the following:
For Common, under Density set the value to 1 kg/m3
For Flow, set Viscosity to 0.01 Pa-s
Under Initial Conditions, for Velocity set the value to 1, 1, 0