PID Controller Overview
This tutorial demonstrates how a Proportional Integral-Derivative (PID) controller works through controller module using Creo Flow Analysis. The objective of mixing pipe flow model simulation is to determine the flow rate of hot fluid, to attain the desired outlet temperature of 39 °C. The following figure shows the geometry and conditions for the mixing pipe-PID controller simulation.
Problem overview— PID Controller
Fluid properties:
Density—997 kg/m3
Viscosity—0.00085 Pa.s
Constant Conductivity—0.613 W/m-K
Specific Heat Capacity—4179 J/kg-K
1. Outlet
Outlet pressure—101325 Pa
2. Cold fluid inlet
Volumetric Flux—1LPM
Temperature—20C
3. Hot fluid inlet
Volumetric Flux—Control variable
Temperature—50C
The exercises in the Flow Analysis simulation are: