To Create Loadcell Reaction Measures
For this procedure you must have used the Analysis Definition dialog box to create a loadcell lock, and either run a force balance analysis, or saved the results of a previous analysis.
1. Click
Measures. The
Measure Results dialog box opens.
2. Click
![](../../simulate/mech_des/images/new.png)
. The
Measure Definition dialog box opens.
3. Type a descriptive name for your measure or accept the default name.
4. Select Loadcell reaction under Type and click OK.
5. If there is no result set in the list, click
![](../../simulate/mech_des/images/open.png)
and browse to find one.
6. Select the result set(s) you want and click OK.
7. Select a result set from the list, and select the loadcell reaction measure. The magnitude of the force is displayed under Value.