Warning | Description | Resolution |
---|---|---|
Missing Upstream Flange/Gasket | Missing flange or gasket or both for a fitting that appears below the warning message on the Piping System Tree | Right-click the warning message on the Piping System Tree and click Insert. |
Missing Downstream Flange/Gasket | Missing flange or gasket or both for a fitting that appears above the warning message on the Piping System Tree | Right-click the warning message on the Piping System Tree and click Insert. |
Invalid Corner | Missing corner fitting or an invalid corner | Right-click the warning message on the Piping System Tree and click Bend or Elbow or Miter. The options appear according to the definition in the Master Catalog. |
STUBIN | Missing branch fitting | Right-click the warning message on the Piping System Tree and click Insert. The missing branch fitting is placed according to the definition in the Master Catalog. |