To Define a Result Window
1. Click
Home >
New and select the results to display in native mode.
2. After you select a results file the
Result Window Definition dialog box opens. In FEM mode, click
Home >
New to open this dialog box.
3. Type a
name to identify the result window so that you can show or hide the window during your results session, or accept the default name.
4. Type a
title that you want to display in the title bar of result window.
5. Select the
design study for which you want to display results by clicking
.
6. If the design study has more than one analysis, select an analysis from the Analysis option menu.
7. If
Creo Simulate displays a
step/combination table below the
Design Study and
Analysis option menus, select a load set, mode, time step, or frequency from the table.
8. Select one of these display types from the Display Type option menu:
◦ Fringe
◦ Vectors
◦ Graph
◦ Model
10. Select
units for the selected quantity or accept the default principal system of units
| Unit selection is not available for analysis created before Wildfire 5.0. |
11. Select the
Display Options tab and choose among the
display options to determine the appearance and behavior of your model in the result window.
12. Select the
Display Location tab and choose a location from the option menu. If you want to use all entities of a certain location type, select the
Use All check box. To select a single entity, click the selector arrow.
13. To display the result window, click OK and Show. To close the dialog box without displaying the result window, click OK.