Repair Imported Geometry
Use Alternate Mass Properties or
Use Calculated Mass Properties
Ignore Solidification Check or
Enable Solidification CheckIf the Associative Topology Bus (ATB) update converts single-body TIM parts and components to TIMs with multiple bodies, the Import Validation Report identifies solidification failures at the body level and reports import validation failure as the overall status of the TIM parts and components with multiple bodies. |
Repair Imported Geometry option is also available in the Notification Center.
Use Calculated Mass Properties and the
Use Alternate Mass Properties options are mutually exclusive. If you have used the
Use Alternate Mass Properties option, the
Use Calculated Mass Properties option is available. The mass property values of the source models are then compared with the alternate or the calculated mass property values of the imported and opened models. The
Use Calculated Mass Properties and the
Use Alternate Mass Properties options are also available in the Notification Center.
Ignore Solidification Check and the
Enable Solidification Check options are mutually exclusive. If you have used
Ignore Solidification Check, the
Enable Solidification Check option is available with which you can restart checking for solidification errors. The
Ignore Solidification Check and the
Enable Solidification Check options are also available in the Notification Center.