ThingWorx Connection Server > Upgrading a ThingWorx Connection Server from 9.2.1 to 9.2.2
Upgrading a ThingWorx Connection Server from 9.2.1 to 9.2.2
This topic explains how to upgrade a ThingWorx Connection Server from version 9.2.1 to 9.2.2 when using the Connection Server in a ThingWorx Single-Server Environment and when using it in a ThingWorx High Availability (HA) Clustering environment. Start with the first section listed, "Best Practices for Upgrading".
Click a section title to display its content. Click the title again to hide the content.
Downloading the Distributon Bundle 
To download the distribution bundle for your operating system, go to the PTC Support site, Software Download page and then
1. Select the Product Family, THINGWORX CONNECTION SERVICES.
2. On the download page for the ThingWorx Connection Services Product Family, the releases are numbered by the related release of ThingWorx Platform. To upgrade, expand the Release 9.3 node.
3. Expand the node, ThingWorx Connection Server, and then the node, Most Recent Datecode.
4. Click HTTPS to download the distribution bundle.
5. Extract the downloaded zip file to an appropriate location.
Upgrading from 9.2.1 to 9.2.2 in a ThingWorx Single-Server Environment 
These are the instructions for upgrading the ThingWorx Connection Server from version 9.2.1 to version 9.2.2 when the Connection Server connects to a ThingWorx single-server environment. It is expected that you have already downloaded and extracted the distribution bundle.
1. As the Always-On Connection Server 9.2.2 uses the same configuration file as Always-On 9.2.1, you can copy the configuration from Always-On 9.2.1 in to the conf directory of Always-On 9.2.2.
2. Be sure to update the environment variables to point to the new configuration file location. For assistance with this step, refer to Setting the Environment Variables for the Connection Server.
3. If you need to make any changes to the Always-On Connection Server 9.2.2s configuration files, do so within the new copy of the configuration file.
* 
If you need to first decrypt the configuration file, see step 5 in the section Encrypting the Configuration File
4. Shut down the v.9.2.1 Connection Server.
5. Start the v.9.2.2 Connection Server.
7. Verify that the Connection Server successfully connected to ThingWorx by confirming it appears in the ThingWorx Composer list of Connection Servers and shows "Running" at the top. To access this page follow these steps:
a. In the left navigation panel of ThingWorx Composer, click the icon (Monitoring menu).
b. Select Connection Servers to display the page.
Upgrading from 9.2.1 to 9.2.2 in a ThingWorx High Availability Clustering Environment 
These instructions explain how to upgrade the Connection Server from version 9.2.1 to 9.2.2 when the Connection Server connects to a ThingWorx High Availability (HA) Clustering environment.
1. As the Always-On Connection Server 9.2.2 uses the same configuration file as Always-On 9.2.1, you can copy the configuration from Always-On 9.2.1 in to the conf directory of Always-On 9.2.2.
2. Be sure to update the environment variables to point to the new configuration file location. For assistance with this step, refer to Setting the Environment Variables for the Connection Server.
3. If you need to make any changes to the Always-On Connection Server 9.2.2s configuration files, do so within the new copy of the configuration file.
* 
If you need to first decrypt the configuration file, see step 5 in the section Encrypting the Configuration File
4. Shut down the v.9.2.1 Connection Server.
5. Start the v.9.2.2 Connection Server.
7. Verify that the Connection Server successfully connected to ThingWorx by confirming it appears in the ThingWorx Composer list of Connection Servers and shows "Running" at the top. To access this page follow these steps:
a. In the left navigation panel of ThingWorx Composer, click the icon (Monitoring menu).
b. Select Connection Servers to display the page.