DA_MODIFY_FIXED_TEMP_EDGE modifies the fixed temperature value on an edge.
-->DA_MODIFY_FIXED_TEMP_EDGE--+
|
+-----------------------------+
|
+---+--+--(:LBC)-------|SELECT S_FERRUM_FIXED_TEMP|--(*1*)--+-->
| | |
| +--(:STUDY)-----|SELECT S_FERRUM_STUDY|--------------+
| | |
| +--(:NAME)------|string|-----------------------------+
| | |
| +--(:REF-ELEM)--|edge|-------------------------------+
^ | |
| +--(:VALUE)-----|temperature|------------------------+
| |
+-------<----------<----------<---------<-----------<---+
The following options are available.
-
:LBC
- specifies the LBC associated with the fixed temperature.
-
:STUDY
- specifies the name of the associated study for the fixed temperature.
-
:NAME
- specifies the name of the fixed temperature to modify.
-
:REF-ELEM
- specifies the part element with the fixed temperature to modify.
-
:VALUE
- specifies the temperature value.
Use this action when modifying fixed temperature on a part in Design Integrity.