There is a 2 mm diameter trimmed ejector
MoldBase has not found an ejector with the current diameter and necessary length in the catalog, the preview will be in BLUE and we will see in preview the original ejector.
You must decide if you want to change the ejector diameter, take a non-standard length or change ejector type or catalog.
* Click the ModifyComp button* Change D1 to 4 (here we have decided to change the ejector diameter)
* Click the accept button in the bottom of this dialog