DA_HEAT_GENERATION simulates the heat being generated by a part.
*6* - only if :DA_TABULAR is set to :ON
-->DA_HEAT_GENERATION--+
|
+----------------------+
|
+---+--+---(:STUDY)-----------|select S_FERRUM_STUDY|-------+-->
| | |
| +---(:NAME)------------|string|----------------------+
| | |
| +---(:REF-ELEM)--------|part|------------------------+
| | |
| +---(:TEMPERATURE)-----|temperature|-------(*6*)-----+
| | |
| +---(:TEMP_INCREMENT)--|temperature-diff|--(*6*)-----+
| | |
| +---(:VALUE)-----------|vol heatflow|----------------+
| | |
| +---(:FACTOR)----------|number|------------(*6*)-----+
^ | |
| +---(:TOTAL-VALUE)-----|heatflow|--------------------+
| | |
| +---(:DELETE_ENTRY)------------------------(*6*)-----+
| | |
| +---(:SET_ENTRY)---------------------------(*6*)-----+
| | |
| +---(:EVALUATE)----------------------------(*6*)-----+
| | |
| +---(:DA_TABULAR)-----------------------+--(:ON)---+-+
| | | | |
| | +--(:OFF)--+ |
| | |
| +---(:NEXT)------------------------------------------+
| |
+-----<-----------<----------<-----------<---------<----+
The following options are available.
-
:DA_TABULAR
- when set to ON
, temperature-dependent heatflows can be entered.
-
:STUDY
- specifies the associated study for the heat generation.
-
:NAME
- specifies the name of the heat generation to create.
-
:REF_ELEM
- specifies the part to apply the heat generation value.
-
:TEMPERATURE
- specifies the part temperature.
-
:TEMP_INCREMENT
- specifies the temperature increments.
-
:VALUE
- specifies a heat generation value to be applied to the part.
-
:FACTOR
- specifies the incremental factor to be used.
-
:TOTAL-VALUE
- specifies a total value to be applied to the part.
-
:DELETE_ENTRY
- deletes an entry.
-
:SET_ENTRY
- sets an entry in the heat generation table.
-
:EVALUATE
- evaluates the heatflow using the temperature value and the factor.
-
:NEXT
- accepts the parameters you have defined and allows you to define the next parameter to apply.
Use this action when calculating a part's heat flux.