Creo Simulate > Creating Analyses > Structural Analysis > Static and Prestress Static Analyses > Convergence Options > To Set Convergence for a Thermal Analysis
  
To Set Convergence for a Thermal Analysis
This procedure assumes you are in the dialog box for creating a steady thermal analysis or a transient thermal analysis.
1. Click the Convergence tab on the analysis dialog box.
2. Select a convergence method for your steady thermal analysis or transient thermal analysis:
Multi-Pass Adaptive (available only for steady thermal analysis)
Single-Pass Adaptive
Quick Check
 
* If you are creating a steady thermal analysis and selected Multi-Pass Adaptive, continue with the following steps.
3. Enter a minimum and maximum polynomial order.
4. Enter a convergence percentage.
5. Select the quantities you want Creo Simulate to use to calculate convergence.