Option
|
Description
|
Values
|
Create/Replace Mesh
|
New mesh or store build mesh.
|
New Mesh, or Store Build Mesh
|
Mesh Name
|
Provide a mesh name.
|
|
Mesh Location
|
Sets the location of the mesh.
|
Interior Volumes, Exterior Volumes, or All Volumes
|
Cell Size Specification
|
Determines whether to use relative or absolute length scales for meshing parameters requiring length, such as those listed below:
• Maximum Cell Size
• Minimum Cell Size
• Cell Size on Surfaces
|
Relative to All CAD Surfaces, Relative to Selected CAD Surfaces, or Absolute
|
Critical Edge Angle
|
Sets the accuracy with which the mesher resolves edges in CAD Surfaces. The lesser the critical edge angle, the better is the resolution of the edges.
|
Default value is 30
|
Curvature Resolution
|
Sets the accuracy with which the mesher resolves curves in CAD Surfaces.
|
Default value is 35.0
|
Maximum Cell Size
|
Sets the size of the cells throughout a mesh volume. It is specified in terms of Relative to All CAD Surfaces, Relative to Selected CAD Surfaces, or Absolute. No cell in the volume can have a cell side larger than the Maximum Cell Size.
|
Default value is 0.02
|
Minimum Cell Size
|
Limits how small cells can attempt to resolve the geometry. The minimum cell size is specified in terms of Relative Size or also applies to all the cells in a volume. No cell in the volume can have a cell side smaller than the Minimum Cell Size.
|
Default value is 0.0007
|
Cell Size on Surfaces
|
Controls the size of the cells for all surfaces of a mesh volume. Cell Size on Surfaces is specified in terms of Relative to All CAD Surfaces, Relative to Selected CAD Surfaces, or Absolute. No cell on the surface can have a cell side larger than the value of Cell Size on Surfaces.
|
Default value is 0.01
|
Create a Refinement Zone
|
Controls the size of the mesh cells within defined zones of a volume. You can create any number of refinement zones. Cells within a zone are subsequently based on Cell Size, which is similar in function to Maximum Cell Size.
When you create a refinement zone, you must set the desired dimensions of the zone geometry and the cell size prior to the meshing operation. The specified value of cell size is applied inside the zone being meshed. A new zone is created each time you click Box Zone Refinement, Cylindrical Zone Refinement or User Defined Refinement. You can remove the zone by selecting Remove This Zone in the Refine Zone Options list.
|
No, Box Zone Refinement, Cylindrical Zone Refinement, or User Defined Refinement
|
Cell Size on Boundaries
|
Controls the size of the boundary cells generated next to an individual CAD Surface. No boundary cell at the selected surface can have a cell size larger than the corresponding Cell Size on Boundaries. It is a length scale specified in terms of Relative Size or Absolute Size. The User Input value of the Cell Size on boundaries is applied only for the selected surface. Smaller values will provide higher resolution.
|
|
Min. Cell Refinement on Boundaries
|
Limits minimum cell size while resolving a CAD geometry using the General Mesher. Also used to provide local refinement on CAD Surfaces that present small features such as tight gaps, sharp curvature etc. They define the number of levels the Minimum Cell Size is decreased by. Three different levels of limiting are offered under Min. Cell Refinement on Boundaries: Refine One Level (half), Refine Two Levels (four times), and Refine Three Levels (eight times).
|
Option
|
Description
|
Values
|
||
Bounding Box Margins
|
Controls how the bounding box is constructed. The bounding box is an imaginary box placed around a volume to be meshed. The bounding box is the starting point for subsequent cell division by the Binary Tree meshing capability.
|
Automatic,Uniform, Nonuniform, or Diagonal Positions
|
||
Cell Size near Critical Edges
|
Controls the size of the cells near a critical edge. This is the edge resolved by the mesh based on the Critical Edge Angle. It is a length scale specified in terms of Relative to All CAD Surfaces, Relative to Selected CAD Surfaces, or Absolute. No interior cell adjacent to critical edge can have a cell side larger than value for Cell Size near Critical Edges.
|
Default value is 0.02
|
||
Cell Size near Critical Points
|
Controls the size of the interior cells near a critical point. This is a point where two critical edges connect. Cell Size near Critical Points is specified in terms of Relative to All CAD Surfaces, Relative to Selected CAD Surfaces, or Absolute. No interior cell near a critical point can have a cell side larger than the value for Cell Size near Critical Edges.
|
Default value is 0.02
|
||
Cell Size on Surface Near Edges
|
Controls the size of the boundary cells near the critical edges. Cell Size on Surface Near Edges is specified in terms of Relative to All CAD Surfaces, Relative to Selected CAD Surfaces, Absolute. No boundary cells adjacent to a critical edge can have a cell side larger than the Cell Size on Surface Near Edges.
|
Default value is 0.02
|
||
Cell Size on Edge Near Points
|
Controls the size of the edges near a critical point. This is a point where two critical edges connect. Cell Size on Edge Near Points is specified in terms of Relative to All CAD Surfaces, Relative to Selected CAD Surfaces, Absolute. No edge adjacent to a critical point can have a cell side larger than the value for Cell Size on Edge Near Points.
|
Default value is 0.02
|
||
Tree Orientation X Axis
|
Sets the orientation of the Bounding Box. The new orientation of the X-Axis for the bounding box is set after you provide the X, Y, and Z components of a vector.
|
You provide the X, Y, and Z components of a vector.
|
||
Tree Orientation Y Axis
|
Sets the orientation of the Bounding Box. The new orientation of the Y-Axis of the bounding box is set after you provide the X, Y, and Z components of a vector.
|
You provide the X, Y, and Z components of a vector.
|
||
Node Merge Tolerance(Distance)
|
Sets the tolerance at which two nodes are merged into a single point. It is specified in terms of Relative to All CAD Surfaces, Relative to Selected CAD Surfaces, Absolute.
|
Default value is 0.000070
|
||
Refine Cells next to Boundary Cells
|
Refines the cells in the transition from one Boundary to the next so that they are of the same order in size. Refine Cells next to Boundary Cells is specified in terms of Relative to All CAD Surfaces, Relative to Selected CAD Surfaces, Absolute.
|
No or Yes
|
||
Parallel Cell Aspect Ratio
|
Controls the aspect ratio of the cells. Parallel Cell Aspect Ratio controls mesh density near the control volume surfaces.
|
A value between 1 and 8. Default value is 2.
|
||
Maximum Cell Proportion
|
Controls the mesh and limits the aspect ratio of the cells.
|
You provide the X, Y, and Z components of a vector.
|
||
Sub-feature Options
|
Controls the grouping subfeatures. When you select Combined with Patches, the Sub-feature Options attaches the subfeatures to the nearest surface. Separate Patches and Separate Volumes show the subfeatures as a separate Boundary and Volume.
|
Combined with Patches, Separate Patches, or Separate Volumes
|
||
Volume Name by Surface Prefix
|
Activates the naming of volumes based on the prefix of the CAD Surface names.
|
No or Yes
|
||
Volume Options
|
Controls the retainment of volumes during meshing. Multiple Volumes retains all volumes and is the default option.
|
Multiple Volumes, Biggest Volume, or Single Volume
|
||
Volume Order by Size
|
Orders volumes based on mesh size, in the Flow Analysis Tree.
|
No or Yes
|
The projection surface determined by the projection method is only used for mapping the boundaries. It does not have to lie between the boundaries to create the connection. |
The name of the external grid file must be in the format of <BaseName><number>. The file contains the coordinates with the header line indicating the number of points in the corresponding file. |