The ISOGEN Endtype Map file is a Pro/TABLE file that maps Spec-Driven Piping end types to corresponding ISOGEN end types. You can modify the ISOGEN Endtype Map file by using a text editor.
The ISOGEN Endtype Map file format is displayed in the next table.
Field Name
Field Type
Description
ENDTYPE
Character
Spec-Driven Piping end type
ISOGEN_ENDTYPE
Character
ISOGEN end type
Default End Type Mapping
If you do not provide an ISOGEN Endtype Map file or if you do not list the entries for the end types used by the Spec-Driven Piping fitting components in the Endtype Map file, Spec-Driven Piping maps the end types by default.
The string matching rules for default end type mapping is listed in the next table.
ENDTYPE
ISOGEN ENDTYPE
endtype string starting with B
BW
endtype string starting with C
CP
endtype string starting with F
FL
endtype string starting with P
PL
endtype string starting with SC
SC
endtype string starting with SW
SW
No match found
BW
 