Displaying Missing Fitting Violations
Spec-Driven Piping
Missed fitting types are displayed under Design Rules Tree in the Design Rules Check dialog box as follows:
Corner Fitting—Displays violation results for missing corner fittings.
Flange-Gasket—Displays violation results for missing gaskets and flanges. The following columns are displayed under Violation Details:
Sname—The selection name of the fitting that has the missing flange and gasket.
Location—The upstream, downstream, or the branch stream location where the violation has occurred.
Non Spec-Driven Piping