To Verify the Availability of Original References
1. Select a copied feature in the Model Tree.
2. Next to
Model Tree, click
>
Tree Columns. The
Model Tree Columns dialog box opens.
3. Under
Not Displayed, select
Copied Refs and click
to move the selected item to the
Displayed section.
4. Click OK. The Status column added to the Model Tree displays the following status of the copied references:
◦ MISSING when the references are deleted. This status is also displayed when the feature is copied across models and the source is in session.
◦ FROZEN when the feature is copied across models and the source is not in session.
◦ SUPPRESSED when the source feature is suppressed.
◦ EXCLUDED when the source feature is excluded in a simplified representation of a part.