Manufacturing > CL Output > Synchronized Output for XY-UV 4-Axis Wire EDM
  
Synchronized Output for XY-UV 4-Axis Wire EDM
The following commands apply to 4-Axis Wire EDM output:
Command
Description
SET/ UPPER, a, LOWER, b
Indicates the Z values of the upper and lower contours. "a" and "b" are real numbers.
CLDIST / c
Indicates the distance that the top head is above the upper contour
n
LOAD / WIRE, n
Indicates that wire "n" should be threaded. "n" is an integer.
GENRTR / n
Indicates the power setting for subsequent motions.
SYNCTR / NEXT, n
Indicates a position where the two heads should be located simultaneously. There will be matching statements in the output of each head.
SYNCTR / LOWER|UPPER
Indicates that subsequent motions will be for lower or upper contour respectively.
UNLOAD / WIRE
Indicates that the wire should be cut.
OPSTOP