Cabling > Using Parameters in Cabling > To Specify Parameter Values for Multiple Objects
  
To Specify Parameter Values for Multiple Objects
1. Click Cabling Parameters. You can select a component in the Model Tree or graphics window, right-click, and choose Cabling Parameters. You are prompted to select a cabling component.
2. To ensure that you select a correct cabling object, click Tools > Find, and select the required object.
or
Select the wires, cables, components, or connectors that you want to modify.
3. Click OK. The Electrical Parameters dialog box opens.
4. Under Display For, select appropriately to show or hide the parameters for different levels of the tree in the left panel. For example, for a component, pin, conductor, entry port, and so on.
5. In the right panel of the dialog box, click multi-select for the object type that you have selected. If a parameter for the object has any nonexistent values, you can change all values, including nonexistent values, to the new value or ignore the Nonexistent values.
If the column has any nonexistent values, you can choose between:
Create and Set—Changes all values, including nonexistent values, to the new value.
Set Existing Only—Ignores nonexistent fields.
6. Type a new value for the parameter in the Value box and press ENTER. The new value for the selected parameter appears in the right panel of the Electrical Parameters dialog box.
7. Click Apply and then OK. All values in a column for a selected object are changed to the new value.
 
* Both the cable or wires and bundles cannot be displayed together in the Electrical Parameters dialog box.