To Create a Terminator
1. Click Logical Data > Terminators. The TERMINATORS menu appears.
2. Click Create.
3. At the prompt, type a new name for the terminator and press ENTER. The Electrical Parameters dialog box opens.
4. Click View > Columns. The Model Tree Columns dialog box opens.
5. Move parameters back and forth from the Not Displayed to the Displayed windows as necessary.
6. If required, define a new parameter by typing the parameter name in the
Name box and clicking
to move it to the
Displayed window. The new parameter is added to the current list with
Nonexistent as the value. This means a value has never been assigned. You can change the value for a single parameter or for multiple parameters.
7. Click Apply and then OK in the Model Tree Columns dialog box.
8. Assign a value to the new parameter in the Electrical Parameters dialog box.
9. Click Apply and then OK to add parameters.