To Configure Allowable Beam Endcope Values
Use the beam_end_cope_dims.cfg file to define allowable beam end cope length and height values. The next largest values are used to maintain user-specified clearance during cope placement, as follows:
H
3
4
5
6
8
10
15
20
25
...
L
10
15
20
25
30
35
40
45
50
55
60
65
70
...
The file begins with the letter H. A list of allowed height values appears after the H (the list is actually longer than shown). The letter L and values for L follow.