Контроль производства > VERIFY > Verification Results > To Compute Deviation Features
  
To Compute Deviation Features
1. On the VER RESULTS menu, click Compute. The SELDEV menu appears.
2. Select the features you want to analyze and then click Done Sel.
The system calculates in order the selected deviation features. The message window indicates which feature is being processed and its deviation type. The working indicator (clock) also appears on the screen and the STOP sign appears in the message window.
3. If you want to stop the calculations, click the STOP sign.