You can then right-click the model with the defective and problem geometry on the Model Tree and click > to access Import DataDoctor (IDD). You can click
Geometry Checks on the
Analyze tab in IDD and use the
Troubleshooter to verify the solidification failure. Verify if the
Solid node with open quilts diagnostic is checked in the
Troubleshooter. A red dot next to the diagnostic identifies it as an error. When you select the
Solid node with open quilts diagnostic in the
Troubleshooter, the defective geometry zooms in. The text area of the
Troubleshooter displays the diagnostic type and the recommended solution. When you repair the bodies of parts that failed to solidify, for instance, repair the quilts of the bodies that failed to solidify until they are closed, the resultant solid geometry populates the bodies. You can further analyze the geometry using diagnostics in IDD to identify defects such as unsatisfied topological connections and tangency conditions and gaps and slivers. You can then use the repair and heal geometry options in IDD to address the defects and resolve validation failures because of defective or incomplete geometry. The
Repair Imported Geometry option is also available in the Notification Center.