Creo Simulate > Modeling Structure and Thermal Problems > Measures > Results Available for Measures
  
Results Available for Measures
Creo Simulate calculates results for a particular measure for certain analysis types only, and gives you the output for the following design study types:
Design Study Type
Output for Measures
standard design study that runs an analysis using the multi-pass convergence method
convergence graph of a measure's value at each polynomial pass of a static, buckling, contact, prestress, modal, or steady-state thermal analysis
standard design study that runs on the vibration analyses or a transient thermal analysis
graph of a measure's value at each time or frequency interval for dynamic time, frequency, transient thermal, and random analyses
standard design study that runs a large deformation analysis or a contact analysis
graph of each measure's value at each load interval
optimization design study
graph of a measure's value at each step
local or global sensitivity study
graph of a measure's value at different settings of a parameter
standard or optimization design study
a value for each valid measure for each analysis
This data is available in the summary file, which you can view online through the Run command or print through your operating system. The summary file does not include values for measures that Creo Simulate calculates at each step of a dynamic analysis.
The types of results listed above are not available for results quantities other than measures. For other results quantities, you can query values at specific locations, view fringe, contour, and vector displays, and graph the value along element edges.
 
* Creo Simulate does not include excluded elements when it calculates measures, except for strain energy measures.
Return to About Simulation Measure.