Creo Simulate > Creating Analyses > Vibration Analysis > Dynamic Time Analysis > To Select Output Options for a Dynamic Time Analysis
  
To Select Output Options for a Dynamic Time Analysis
Use this procedure if you are creating a dynamic time analysis.
1. Click the Output tab on the analysis dialog box.
2. Select the quantities that you want Creo Simulate to calculate.
3. Select an option to specify the Output Steps for which you want results—Automatic steps within range or User-defined output steps.
If you select User-defined output steps, different items appear on the tab. Skip to steps 5 through 8.
4. If you selected Automatic steps within range, you can specify a Time Range over which you want Creo Simulate to report results for your analysis:
Type the minimum time for the time range. You can select Automatic to use the default maximum time or User-defined to specify a different maximum time.
 
* If you selected Automatic steps within range, go to Step 8.
5. Type a value for Number of master steps in the time range at which you want results reported. Creo Simulate displays the specified number of rows in the list of master steps.
6. Use the default values for each time step to specify the difference between steps or click the User-defined steps button to specify values.
If you click User-defined steps, you can use the Space Equally button to evenly space the steps.
7. Select the check boxes next to the steps for which you want to compute and save full results.
You can also select for full results at all steps or select to turn off full results for all steps.
8. Type a non zero number for Measures output steps per master step.
Return to To Create a Dynamic Time Analysis.