Misure automatiche (CMM) > CMM Process > To Modify CMM Steps
  
To Modify CMM Steps
1. Click Inspect > Operate > Modify CMM > Mod CMM Step. A namelist menu of the steps appears.
2. Select the name of the step from a namelist menu. Only Measure and Auxiliary steps are listed.
3. Use the following options:
Probe—Change the probe, the tip, or orientation.
Dimensions—Modify dimensions associated with the step, if any.
Parameters—Modify the CMM parameters of the step.
Motion Params–Modify the probe motion parameters.