Progettazione elettrica > Editing Wire Labels > To Set Up Wire Label Defaults
  
To Set Up Wire Label Defaults
1. Click File > Properties to set up the wire label contents and position. The Options dialog box opens.
2. Use the following setup options:
label_default_position
Position of labels on wire lines. Can be START, MIDDLE, END or any combination separated by commas.
label_ends_gap
Distance between nodes and labels. Numeric value
label_parallel
If YES, the wire label is always parallel to the wire, if NO, labels are always parallel to the orientation of the sheet.
def_wire_label
Sets the default string to display in the wire label.
default_wire_label_style
Sets the default wire label style, which is a user-defined text style.
default_wire_line_style
Sets the default wire line style, which is a user-defined text style or a system line style.
wire_default_increment
Defines the increment numerical value between two consecutively created wires. Used with wire default-prefix and wire-default suffix.
wire_default_prefix
Defines the text prefix of default wire names.
wire_default_suffix
Defines the start number or letter of the default wirename. If wire_default_suffix is 1, and wire_default_increment is 2, consecutive wires are named wire1, wire3, wire5, and so on. If wire_default_suffix is A, and wire_default_increment is 2, consecutive wires are named wireA, wireC, wireE, and so on. (Cannot contain underscores, dashes, or a mix of numerical and alphabetical characters.)
wire_notes_above
If Yes, the wire notes are set above the wire. If No, they intersect the wire. You can also enter a real number for exact offset from the wire.