Machines à mesures tridimensionnelles (CMM) > Probe Path > Process Information > To Output CMM Process Information
  
To Output CMM Process Information
1. Choose Tools > Manufacturing Info. The system displays the Manufacturing Info dialog box.
2. Select the type of report you want using the option buttons in the top portion of the dialog box:
Manufacturing Model—Output information about the whole CMM process. You can configure types of information to output using the Filter button. All operations and all CMM steps will be output according to their current Filter configurations. CMM steps will be sorted by operations.
Operation—Output information about selected operation(s). Select the operation names from the list box. You can configure types of information to output using the Filter button. All CMM steps included in the selected operations will be output according to the current Filter configuration for the CMM step.
CMM Step—Output information about selected CMM step(s). You can configure types of information to output using the Filter button.
3. Use the Screen and File checkboxes to specify if you want to output information on the screen, to a file, or both.
4. Click Apply to output information.